Welcome to The Underwater Sound Reference Division

Model Information (PDF) Summary

Introduction

Transducer characteristics, measurements, units, model designations, and services information.

A48

A48

Hydrophone 100 Hz to 200 kHz

Added Calibration 10 Hz to 100 Hz

E8

E8

Projector 200 kHz to 2 MHz

E27

E27

Projector 80 kHz to 700 kHz

E37

E37

Projector 80 kHz to 2 MHz

F27

F27

Projector 1 kHz to 40 kHz

F30

F30

Projector 10 kHz to 150 KHz

F33

F33

Projector 1 kHz to 50 kHz (Both Arrays)

Projector 15 kHz to 150 kHz (Inner Array Only)

F36

F36

Hydrophone 100 Hz to 20 kHz

Projector 1 kHz to 20 kHz

Added calibration 10 Hz to 100 Hz

F37

F37

Hydrophone 100 Hz to 1 kHz

Projector 1 kHz to 37 kHz

Added Calibration 10 Hz to 100 Hz

F40

F40

Hydrophone 100 Hz to 1 kHz

Projector 1 kHz to 20 kHz

F41

F41

Projector 15 kHz to 150 kHz

F42A

F42A

Hydrophone 100 Hz to 1 kHz

Projector 1 kHz to 40 kHz

F42B

F42B

Hydrophone 100 Hz to 2 kHz

Projector 2 kHz to 50 kHz

F42C

F42C

Hydrophone 100 Hz to 4 kHz

Projector 4 kHz to 90 kHz

F42D

F42D

Hydrophone 100 Hz to 6 kHz

Projector 6 kHz to 150 kHz

F50

F50

Hydrophone 100 Hz to 10 kHz

Projector 10 kHz to 70 kHz

Added Calibration 10 Hz to 100 Hz

F56

F56

Hydrophone 100 Hz to 1 kHz

Projector 1 kHz to 15 kHz

Added Calibration 10 Hz to 100 Hz

F82

F82

Projector 1 kHz to 50 kHz (Both Arrays)

Projector 15 kHz to 150 kHz (Inner Array Only)

Dual aperture for beam width control

F83

F83

Hydrophone 10 kHz to 200 kHz

Projector 10 kHz to 200 kHz

Constant 8 degree beam between 40 kHz to 200 kHz

Ambient to 1000 psi pressure

G34

G34

Projector 200 Hz to 5 kHz

H52

H52

Hydrophone 100 Hz to 150 kHz

Added Calibration 20 Hz to 100 Hz

H56

H56

Hydrophone 100 Hz to 65 kHz

Added Calibration 10 Hz to 100 Hz

H91

H91

Hydrophone 100 Hz to 10 kHz

Added Calibration 10 Hz to 100 Hz

H105

H105

Hydrophone 100 Hz to 65 kHz

Added calibration 10 Hz to 100 Hz

-10 dB FFVS increase over F56

J-Series Special explanation because the design and use is different than piezoelectric transducers (they usethe electro dynamic or moving coil principle).
J9

J9

Projector 40 Hz to 20 kHz

J11

J11

Projector 30 Hz to 10 kHz

J13

J13

Projector 30 Hz to 3 kHz

J15-1

J15-1

Projector 30 Hz to 900 Hz

J15-3

J15-3

Projector 20 Hz to 600 Hz

Portable Calibrators

Types G19 and G40 with an F61 Standard Hydrophone

G19

G19 (see Portable Calibrators above)

Calibrator 100 Hz to 1 kHz

G40

G40 (see Portable Calibrators above)

Calibrator 100 Hz to 1 kHz

F61

F61 (see Portable Calibrators above)

Hydrophone 100 Hz to 1 kHz

Added Calibration 10 Hz to 100 Hz

Appendix A

Coordinate System for Transducer Orientation

Appendix B

Voltage Coupling Loss Measurement

Appendix C

Unit Conversions

Appendix D

Preparation for Use for All Types of Transducers

Appendix E

Active or Scuba Compensation Systems